Here is a complete list of commands for a front-end chip. See
Table 8 for actual bit streams. Below are
brief explanations on the commands.
- Load control register
- Loads control register of the front-end chip.
- Read event
- Starts the front-end chip shifting data out.
- End read-event
- Stops the front-end chip shifting data out.
- Clear event
- Clear one event in FIFO.
- Calibration strobe
- Injects a test pulse into specified channel(s).
- Reset chip
- Reset command decoders, control registers, and FIFO.
- Reset FIFO
- Reset all the contents of FIFO.
Masaharu Hirayama