Minutes from the meeting at SLAC on 20 April 2000 present: Alec, BJ, Derek, Eduardo, Gary, Gwelen, John, Ossie, Takanobu 1) We agreed on the recent design from SLAC on the ladder jig. Alignment pins will be made of glass filled Delrin and a camera and a rail to move the camera will be attached for visual inspection of the fiducials or detector edges. The visual inspection will work as a cross check since we still rely on the alignment using the edges. Visual inspection will also verify the thickness and completeness of the adhesive bond line. The fixture will also accomodate independent vacuum lines. We decide to have 4 posts and the center post will be added only if needed (although lines will be physically present). The base plate thickness will be increased to 1 in. and will be made out of Al tooling plate. If the fixture needs to be put in an oven the base plate could be made out of Invar, but would cost more to manufacture. 2) The gluing dispensing procedure will be made using ideas from both SLAC and UCSC. John is developing a system (mostly based on the old one) to create a thin and controlled layer of glue. The positioning and dipping of detectors will use the method suggested by UCSC. BJ will draw and John will prototype the glue dipping apparatus. Concept drawing will come at next week's meeting. It was noted that the new detectors are too large to be held on their edges by hand. The general handling concept for now is 1. Slide out of envelope onto table 2. Remove paper top cover 3. Pick up with special vacuum tool and place on glue dipping apparatus 4. Pick off apparatus with same vacuum pickup and place on ladder jig. Details will come in drawings, too hard to explain by email. For this week's meeting we will have conceptual drawings only. 3) Eduardo reported a conversation with GLAST material engienneer taht strongly suggested we move away from UV systems (he will give us more feedback as soon as possible). 4) The fixture/procedure for aligning detectors on trays was discussed. We converged on a concept incorporating SCIPP's overhead CCD camera for edge or fiducial alignment and SLAC's vacuum platen to hold detectors in X,Y,Z while curing. We discussed applying adhesives in a way to minimize trapped air. No one was identified to lead the search for the adhesive(s) to attach detectors. John agreed to present a concept drawing for detector alignment using a platen. 5) It was agreed that we need a minimum of 32 mechanical detectors to adequately test the first jig (ideally 50-100). Eduardo said he would investigate the availability of 9.5 cm. square detectors for prototyping. If there are not enough available we will design the first jig for 6.5 x 10.6 cm. detectors which are more available. Action lists: 1- BJ and John will complete the drawings for the jig and the glue dipping apparatus 2- Eduardo will send more info to GSFC to help in settling the UV gluing issue and get requiremenst document written. 3- Ossie will investigate localized heat curing as a fall back solution for UV. 4- Ossie will try to measure flatness of mechanical silicon wafers using gauges to undrestand if a center vacuum post is needed. 5-Eduardo will find out if we can get at least 32 6.5 cm. square mechanical detectors