VMIC DAC 4116
VME parameter
address | A16 |
base address | 0x60 |
address range | 0x60 - 0x7E (16 words) |
data access | supervisory |
Only the first 9 words off the address range are used (0x60-0x70).
Operation
- Enable all output channels:
- vxiout 0x5, baseAdrs+0x10, 0x2, 0x43
Interactive Tests
- vxiout 0x5, 0x70, 0x2, 0x4000
- Change bit 14 in the controll register. 0x4000 turns the LED off.
(0x70 = baseAdrs + 0x10)
Connector
Lab
Last modified: Fri Oct 27 10:47:19 PDT 2000