Author: SCIPP_ATLAS,
date: October 18, 1995 (modified), October 10, 1995 (created)
This is a list of runs related to the binary read out detectors. The infornations were extracted from the log book, but i don't know how reliable they are. If you find a mistake or some information should be added send me a mail.
Run # Tape# Threshold # Events Angle Bias Voltage Module Arrangement Comment .file# 638 LE9390 30,000 0 deg ATT3=70, ATT3, UCSC, DDR2, LBIC1 UCSC=100,DDR2=100,LBIC1=60 639 LE9393.1 bc0.6 640 .2 bc0.8 42,000 641 642 643 644 LE9394.1 bc1.0 60,000 645 .2 wrong 1.2 15,555 646 .3 bc1.2 45,000 648 LE9395.1 bc1.4 60,000 649 .2 bc1.7 56,602 651 LE9396.1 ? 15,000 652 .2 bc2.0 ? 653 .3 bc2.5 6,192 DAQ Freezes 654 LE9397.1 bc2.5 10,000 657 LE9398.1 bc3.0 ? 658 .2 bc3.5 ? 659 .3 bc4.0 660 .4 ? 6,027 ATT3=95, ATT3 & LBIC1 Tripped UCSC=200,DDR2=100,LBIC1=90 661 .5 bc0.6 15,000 ATT3=85, UCSC=200,DDR2=130,LBIC1=85 662 LE9399.1 bc0.8 60,000 Beam off for >2 hours during run 663 .2 bc1.0 0 DAQ Freezes 664 LE9400.1 bc1.0 60,000 665 .2 bc1.2 38,455 Run stopped with Beam OFF 666 .3 bc1.2 1,565 Run stopped because of no beam 672 LE9421.1 bc1.4 60,000 673 LE9422.1 bc1.7 60,000 ATT3=80, DDR2 tripped off before event 17000. UCSC=200,DDR2=130,LBIC1=85 Restore DDR2 to 130 at event 17000. Other voltages also adjusted at event 17000. 674 LE942.1 bc2.0 15,000 Event rate now ~60/spill. Lower intensity and longer deadtime. 675 .2 bc2.5 15,000 676 .3 bc3.0 15,000 677 .4 bc3.5 10,000 678 .5 bc4.0 10,000 679 LE942.1 ac0.8 10,000 ATT3=85, UCSC, ATT3, LBIC1, In addition to reordering modules, they UCSC=150,DDR2=100,LBIC1=60 DDR2 were rotated top to bottom to keep 6cm planes in the beam. 680 LE9425.1 ac1.0 5,000 681 .2 ac1.0 25,000 Beam off for 40min during run. 682 .3 ac1.0 10,000 683 .4 ac1.0 10,000 684 .5 ac1.2 15,000 685 LE9426.1 ac1.2 10,000 686 .2 bc1.2 175 No Beam 687 .3 rc0.2 1,000 Random triggers 688 .4 rc0.3 Random triggers 689 .5 rc0.4 Random triggers 690 .6 rc0.5 Random triggers 691 .7 ac1.2 ? no beam 692 .8 ac1.2 0 693 .9 ac1.2 10,000 694 .10 ac1.2 12,408 695 LE9427.1 ac1.2 10,000 696 .2 ac1.4 10,000 697 .3 ac1.7 10,000 698 .4 ac3.0 10,000 699 .5 ? ? 700 .6 ac4.0 10,000 701 .7 ac0.8 10,000 -7 deg 702 .8 ac1.0 DAQ problems 703 LE9428.1 ac1.0 10,000 704 .2 ac1.0 10,000 705 .3 ac1.0 7,498 Beam energy dropped to 50Gev 706 LE9429.1 ac1.0 5,000 Bias voltages off 707 .2 ac1.2 50,000 Bias voltages off 708 LE9430.1 ac1.4 34,852 Bias voltages off 709 .2 ac1.2 42,773 ATT3=85, Voltages restored. Beam off and on UCSC=150,DDR2=100,LBIC1=60 during run. 710 LE9431.1 ac1.4 10,000 711 .2 ac2.0 10,000 712 .3 ac3.0 10,000 713 .4 ac1.0 8,780 -14 deg 714 LE9432.1 ac1.0 7,000 -14 deg DUT modules moved up 3mm. Old position=163, new position=153. 715 LE9433.1 ac1.0 50,000 Beam off for 15min at ~10000event 716 ? 717 ? 718 ? 719 ? 720 LE9434.1 ac0.8 ? 721 LE9435.1 ac1.2 30,035 722 .2 ? ? 723 .3 ac1.4 10,000 724 .4 ac1.7 ? DAQ killed. This may be on purpose at end of run. 725 LE9436.1 ac3.0 ? No events. Run killed 726 .2 ac3.0 10,000 727 .3 ac4.0 10,000 728 .4 ac2.0 10,000 729 .5 ac1.2 ? Run killed due to no triggers. 730 LE9437.1 ac1.2 141 Run killed to reload felix sequencer 731 .2 ac1.2 10,000 732 .3 ac1.2 1,202 Run killed to reload felix sequencer. DAQ killed. 733 LE9438.1 ac1.2 10,000 734 .2 ac1.2 10,000 735 .3 ac1.2 10,000 736 LE9439.1 ac1.2 0 No beam. tape restarted. 737 .2 ac1.2 30,000 738 LE9440.1 rc0.2 5,000 739 .2 rc0.3 2,000 740 .3 rc0.4 2,000 741 .4 rc0.5 2,000 742 .5 rc0.6 2,000 743 .6 rc0.7 2,000 744 .7 rc1.0 5,000