SN 259 Pre-Encap summary


SN
259
Status
Pre-Encap
Test Result
Pass*
Operator
rlw
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/19 12:16:25
End Time
2004/04/19 12:34:14
Dead or Hot channels
[(19,30),(19,31)]
Bad Gain or Noise channels
[(19,30),(19,31)]
Bad trigger channels
No Data
Number of bad response channels
2
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6086
4.0 0.9511
6.0 1.5164
8.0 2.3725
10.0 2.7358
15.0 5.8145
20.0 8.3412
Bias_V (V) Bias_I (nA)
30.0 21.3943
40.0 29.5463
50.0 36.9462
60.0 40.8224
70.0 46.0795
80.0 50.5422
90.0 50.6952
Bias_V (V) Bias_I (nA)
100.0 52.8429
110.0 51.6944
120.0 52.7932
130.0 54.8535
140.0 54.0363
150.0 54.1547
160.0 54.2002
Bias_V (V) Bias_I (nA)
170.0 54.5920
180.0 53.4549
190.0 52.0710
200.0 52.4970

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection

Pitch adapter bias connection