SN 261 Pre-Encap summary


SN
261
Status
Pre-Encap
Test Result
Pass
Operator
Mutsumi
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/30 09:29:24
End Time
2004/04/30 09:47:55
Dead or Hot channels
[]
Bad Gain or Noise channels
[]
Bad trigger channels
No Data
Number of bad response channels
0
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5945
4.0 0.8715
6.0 1.2969
8.0 1.7992
10.0 2.1270
15.0 4.3378
20.0 5.7108
Bias_V (V) Bias_I (nA)
30.0 13.6871
40.0 19.1402
50.0 26.0904
60.0 34.8280
70.0 38.8619
80.0 42.6487
90.0 44.9408
Bias_V (V) Bias_I (nA)
100.0 44.1728
110.0 45.8406
120.0 45.1058
130.0 46.4698
140.0 47.0311
150.0 48.0791
160.0 48.2122
Bias_V (V) Bias_I (nA)
170.0 48.0681
180.0 47.6335
190.0 47.4374
200.0 50.8714

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection

Pitch adapter bias connection