SN 307 Pre-Encap summary


SN
307
Status
Pre-Encap
Test Result
Pass
Operator
rlw
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/05 13:57:52
End Time
2004/05/05 14:20:10
Dead or Hot channels
[]
Bad Gain or Noise channels
[]
Bad trigger channels
No Data
Number of bad response channels
0
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6353
4.0 1.0721
6.0 1.5112
8.0 1.9838
10.0 2.4588
15.0 4.8210
20.0 6.2473
Bias_V (V) Bias_I (nA)
30.0 14.0803
40.0 20.4662
50.0 21.4565
60.0 24.2608
70.0 25.9763
80.0 27.7550
90.0 30.0914
Bias_V (V) Bias_I (nA)
100.0 31.8165
110.0 33.2211
120.0 34.9826
130.0 33.6155
140.0 37.2669
150.0 37.4084
160.0 39.4798
Bias_V (V) Bias_I (nA)
170.0 40.7339
180.0 43.2025
190.0 45.3514
200.0 48.7410

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection

Pitch adapter bias connection