SN 308 Final summary


SN
308
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/19 08:56:57
End Time
2004/04/19 09:14:28
Dead or Hot channels
[]
Bad Gain or Noise channels
[]
Bad trigger channels
No Data
Number of bad response channels
0
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.8049
4.0 1.4463
6.0 2.0424
8.0 2.6875
10.0 3.4080
15.0 6.7139
20.0 9.1214
Bias_V (V) Bias_I (nA)
30.0 22.6750
40.0 33.2903
50.0 35.9989
60.0 41.7616
70.0 43.6902
80.0 48.8020
90.0 50.0211
Bias_V (V) Bias_I (nA)
100.0 51.0656
110.0 51.8057
120.0 53.6800
130.0 52.9564
140.0 52.6085
150.0 50.3030
160.0 52.3352
Bias_V (V) Bias_I (nA)
170.0 51.3361
180.0 53.2422
190.0 54.4209
200.0 52.6264

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection

Pitch adapter bias connection