SN 308 Pre-Encap summary


SN
308
Status
Pre-Encap
Test Result
Pass
Operator
mutsumi
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/13 14:05:44
End Time
2004/04/13 14:23:13
Dead or Hot channels
[]
Bad Gain or Noise channels
[]
Bad trigger channels
No Data
Number of bad response channels
0
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6798
4.0 1.2632
6.0 1.7454
8.0 2.3741
10.0 3.0556
15.0 6.3447
20.0 9.1120
Bias_V (V) Bias_I (nA)
30.0 22.6616
40.0 30.1075
50.0 37.5366
60.0 42.0802
70.0 49.3617
80.0 52.4718
90.0 54.3994
Bias_V (V) Bias_I (nA)
100.0 56.5838
110.0 59.8495
120.0 61.6129
130.0 61.1043
140.0 62.0308
150.0 62.3069
160.0 62.0989
Bias_V (V) Bias_I (nA)
170.0 63.4447
180.0 64.0303
190.0 62.4740
200.0 61.9295

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection

Pitch adapter bias connection