SN 303 Pre-Encap summary


SN
303
Status
Pre-Encap
Operator
mutsumi
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/13 16:23:42
End Time
2004/04/13 16:42:03
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5841
4.0 0.9557
6.0 1.3761
8.0 1.8789
10.0 2.3946
15.0 5.2694
20.0 7.6198
Bias_V (V) Bias_I (nA)
30.0 23.5456
40.0 28.4812
50.0 35.3314
60.0 42.4645
70.0 45.7367
80.0 48.6702
90.0 50.8761
Bias_V (V) Bias_I (nA)
100.0 54.4475
110.0 55.7063
120.0 56.5429
130.0 56.0324
140.0 56.0516
150.0 55.3145
160.0 57.0770
Bias_V (V) Bias_I (nA)
170.0 56.3644
180.0 56.6778
190.0 55.5833
200.0 54.1972

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)