SN 261 Pre-Encap summary


SN
261
Status
Pre-Encap
Test Result
Fail
Operator
rlw
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/19 09:45:22
End Time
2004/04/19 10:04:58
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5392
4.0 0.9351
6.0 1.7681
8.0 3.3845
10.0 3.9986
15.0 9.4656
20.0 12.7344
Bias_V (V) Bias_I (nA)
30.0 31.6539
40.0 2000.0920

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)