SN 1109 Pre-Encap summary


SN
1109
Status
Pre-Encap
Test Result
Fail
Operator
Marcus
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Tall(899)
Start Time
2004/04/26 12:10:38
End Time
2004/04/26 12:21:09
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6362
4.0 1.0790
6.0 1.5823
8.0 2.2391
10.0 2.8858
15.0 6.4682
20.0 8.5650
Bias_V (V) Bias_I (nA)
30.0 23.3763
40.0 30.5118
50.0 37.5477
60.0 41.9728
70.0 47.9084
80.0 48.4695
90.0 54.1098
Bias_V (V) Bias_I (nA)
100.0 54.4956
110.0 57.6037
120.0 58.0101
130.0 57.7933
140.0 58.8152
150.0 58.8289
160.0 59.5010
Bias_V (V) Bias_I (nA)
170.0 59.6080
180.0 58.8682
190.0 58.1719
200.0 56.3751

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)