SN 304 Pre-Encap summary


SN
304
Status
Pre-Encap
Test Result
Pass
Operator
mutsumi
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/13 13:14:50
End Time
2004/04/13 13:32:15
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5355
4.0 0.8854
6.0 1.3914
8.0 1.9023
10.0 2.4447
15.0 5.3672
20.0 7.8970
Bias_V (V) Bias_I (nA)
30.0 21.7709
40.0 30.1226
50.0 35.5770
60.0 43.0391
70.0 47.1145
80.0 49.9416
90.0 51.3761
Bias_V (V) Bias_I (nA)
100.0 54.6244
110.0 57.0701
120.0 57.0592
130.0 57.4053
140.0 57.9202
150.0 57.1920
160.0 58.5261
Bias_V (V) Bias_I (nA)
170.0 56.9561
180.0 56.1844
190.0 56.2809
200.0 55.8583

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)