SN 308 Final summary


SN
308
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/19 08:56:57
End Time
2004/04/19 09:14:28
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.8049
4.0 1.4463
6.0 2.0424
8.0 2.6875
10.0 3.4080
15.0 6.7139
20.0 9.1214
Bias_V (V) Bias_I (nA)
30.0 22.6750
40.0 33.2903
50.0 35.9989
60.0 41.7616
70.0 43.6902
80.0 48.8020
90.0 50.0211
Bias_V (V) Bias_I (nA)
100.0 51.0656
110.0 51.8057
120.0 53.6800
130.0 52.9564
140.0 52.6085
150.0 50.3030
160.0 52.3352
Bias_V (V) Bias_I (nA)
170.0 51.3361
180.0 53.2422
190.0 54.4209
200.0 52.6264

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)