SN 344 Pre-Encap summary


SN
344
Status
Pre-Encap
Test Result
Fail
Operator
Mutsumi
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/29 13:04:32
End Time
2004/04/29 13:12:00
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5761
4.0 0.9366
6.0 1.3435
8.0 2.4342
10.0 3.0474
15.0 6.6133
20.0 8.8948
Bias_V (V) Bias_I (nA)
30.0 22.0125
40.0 28.1885
50.0 33.6180
60.0 37.9130
70.0 38.2101
80.0 43.4014
90.0 44.8459
Bias_V (V) Bias_I (nA)
100.0 47.5283
110.0 44.5619
120.0 49.3513
130.0 49.3687
140.0 48.1287
150.0 48.8667
160.0 48.3398
Bias_V (V) Bias_I (nA)
170.0 50.0514
180.0 57.3112
190.0 52.0277
200.0 53.6977

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)