SN 346 Pre-Encap summary


SN
346
Status
Pre-Encap
Test Result
Pass
Operator
Mutsumi
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/29 11:59:41
End Time
2004/04/29 12:18:37
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5698
4.0 1.0455
6.0 1.6797
8.0 2.3599
10.0 2.9324
15.0 5.9091
20.0 7.7512
Bias_V (V) Bias_I (nA)
30.0 18.2498
40.0 23.3129
50.0 27.3694
60.0 29.7553
70.0 32.7651
80.0 34.1472
90.0 34.3477
Bias_V (V) Bias_I (nA)
100.0 35.4016
110.0 36.0756
120.0 38.0179
130.0 36.7493
140.0 39.0455
150.0 36.9232
160.0 37.8984
Bias_V (V) Bias_I (nA)
170.0 39.7329
180.0 39.2165
190.0 41.6077
200.0 43.0348

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)