SN 358 Final summary


SN
358
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/19 07:14:44
End Time
2004/04/19 07:33:24
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.8223
4.0 1.4241
6.0 1.9593
8.0 2.5866
10.0 3.2688
15.0 6.6362
20.0 8.9799
Bias_V (V) Bias_I (nA)
30.0 23.6341
40.0 31.8094
50.0 39.0046
60.0 42.6965
70.0 46.9684
80.0 50.0615
90.0 52.6656
Bias_V (V) Bias_I (nA)
100.0 54.5772
110.0 54.2749
120.0 55.6203
130.0 55.3017
140.0 56.9249
150.0 55.1165
160.0 55.9753
Bias_V (V) Bias_I (nA)
170.0 55.0623
180.0 54.7620
190.0 53.6438
200.0 54.6175

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)