SN 296 Pre-Encap summary


SN
296
Status
Pre-Encap
Test Result
Fail
Operator
rlw
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/05 16:23:54
End Time
2004/05/05 16:43:25
Dead or Hot channels
[(20,0),(20,1),(20,2),(20,3),(20,4),(20,5),(20,6),(20,7),(20,8),(20,9),(20,10),(20,11),(20,12),(20,13),(20,14),(20,15),(20,16),(20,17),(20,18),(20,19),(20,20),(20,21),(20,22),(20,23),(20,24),(20,25),(20,26),(20,27),(20,28),(20,29),(20,30),(20,31),(20,32),(20,33),(20,34),(20,35),(20,36),(20,37),(20,38),(20,39),(20,40),(20,41),(20,42),(20,43),(20,44),(20,45),(20,46),(20,47),(20,48),(20,49),(20,50),(20,51),(20,52),(20,53),(20,54),(20,55),(20,56),(20,57),(20,58),(20,59),(20,60),(20,61),(20,62),(20,63)]
Bad Gain or Noise channels
[(20,0),(20,1),(20,2),(20,3),(20,4),(20,5),(20,6),(20,7),(20,8),(20,9),(20,10),(20,11),(20,12),(20,13),(20,14),(20,15),(20,16),(20,17),(20,18),(20,19),(20,20),(20,21),(20,22),(20,23),(20,24),(20,25),(20,26),(20,27),(20,28),(20,29),(20,30),(20,31),(20,32),(20,33),(20,34),(20,35),(20,36),(20,37),(20,38),(20,39),(20,40),(20,41),(20,42),(20,43),(20,44),(20,45),(20,46),(20,47),(20,48),(20,49),(20,50),(20,51),(20,52),(20,53),(20,54),(20,55),(20,56),(20,57),(20,58),(20,59),(20,60),(20,61),(20,62),(20,63)]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6372
4.0 0.7656
6.0 1.5519
8.0 2.2090
10.0 2.8733
15.0 6.0613
20.0 8.4014
Bias_V (V) Bias_I (nA)
30.0 20.9756
40.0 28.4645
50.0 35.1101
60.0 41.5902
70.0 46.4520
80.0 51.2587
90.0 52.9192
Bias_V (V) Bias_I (nA)
100.0 54.8288
110.0 55.0395
120.0 56.4888
130.0 56.9939
140.0 58.0669
150.0 58.4175
160.0 58.3645
Bias_V (V) Bias_I (nA)
170.0 58.3965
180.0 58.2130
190.0 59.2893
200.0 56.9937

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)