SN 1100 Pre-Encap summary


SN
1100
Status
Pre-Encap
Test Result
Pass
Operator
Mutsumi
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Tall(899)
Start Time
2004/04/30 15:58:12
End Time
2004/04/30 16:16:30
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.8871
4.0 1.5152
6.0 2.1583
8.0 2.9087
10.0 3.6430
15.0 7.2573
20.0 9.5935
Bias_V (V) Bias_I (nA)
30.0 24.4030
40.0 31.1062
50.0 34.7709
60.0 37.4521
70.0 39.7666
80.0 43.8569
90.0 44.7440
Bias_V (V) Bias_I (nA)
100.0 43.2487
110.0 47.0329
120.0 45.9187
130.0 48.5379
140.0 48.2046
150.0 48.2756
160.0 48.6783
Bias_V (V) Bias_I (nA)
170.0 49.8248
180.0 50.8867
190.0 51.0204
200.0 52.3208

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)