SN 235 Final summary


SN
235
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Tall(899)
Start Time
2004/05/07 07:37:01
End Time
2004/05/07 07:54:58
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.9826
4.0 2.0941
6.0 3.1544
8.0 1.6754
10.0 5.8588
15.0 5.6872
20.0 8.6278
Bias_V (V) Bias_I (nA)
30.0 15.7344
40.0 19.2405
50.0 20.4514
60.0 28.0403
70.0 28.2247
80.0 31.0069
90.0 31.9638
Bias_V (V) Bias_I (nA)
100.0 32.4369
110.0 34.2811
120.0 36.0658
130.0 37.3159
140.0 38.5624
150.0 38.8361
160.0 39.1353
Bias_V (V) Bias_I (nA)
170.0 41.1351
180.0 42.3111
190.0 41.7853
200.0 44.4481

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)