SN 237 Final summary


SN
237
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Tall(899)
Start Time
2004/05/07 07:14:47
End Time
2004/05/07 07:33:29
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 -1.1408
4.0 3.9516
6.0 2.8858
8.0 3.0231
10.0 4.4192
15.0 4.7405
20.0 6.3526
Bias_V (V) Bias_I (nA)
30.0 9.7064
40.0 10.1260
50.0 14.4993
60.0 16.0177
70.0 17.9135
80.0 19.8002
90.0 22.0292
Bias_V (V) Bias_I (nA)
100.0 20.8605
110.0 22.6369
120.0 22.5426
130.0 24.8394
140.0 26.0804
150.0 24.1736
160.0 25.8703
Bias_V (V) Bias_I (nA)
170.0 27.5488
180.0 27.8747
190.0 30.3883
200.0 34.9501

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)