SN 261 Pre-Encap summary


SN
261
Status
Pre-Encap
Test Result
Pass
Operator
Mutsumi
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/30 09:29:24
End Time
2004/04/30 09:47:55
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5945
4.0 0.8715
6.0 1.2969
8.0 1.7992
10.0 2.1270
15.0 4.3378
20.0 5.7108
Bias_V (V) Bias_I (nA)
30.0 13.6871
40.0 19.1402
50.0 26.0904
60.0 34.8280
70.0 38.8619
80.0 42.6487
90.0 44.9408
Bias_V (V) Bias_I (nA)
100.0 44.1728
110.0 45.8406
120.0 45.1058
130.0 46.4698
140.0 47.0311
150.0 48.0791
160.0 48.2122
Bias_V (V) Bias_I (nA)
170.0 48.0681
180.0 47.6335
190.0 47.4374
200.0 50.8714

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)