SN 302 Pre-Encap summary


SN
302
Status
Pre-Encap
Test Result
Pass
Operator
albert
TE_Config
009
Software_V
rel-1-3-4
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/10 13:23:33
End Time
2004/05/10 13:41:51
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5726
4.0 1.0486
6.0 1.4238
8.0 1.9263
10.0 2.3072
15.0 5.4836
20.0 8.0233
Bias_V (V) Bias_I (nA)
30.0 22.5124
40.0 29.1068
50.0 36.7336
60.0 43.2439
70.0 47.7955
80.0 50.1927
90.0 51.3940
Bias_V (V) Bias_I (nA)
100.0 56.1945
110.0 55.4864
120.0 58.3785
130.0 57.9110
140.0 59.2126
150.0 59.0133
160.0 58.8700
Bias_V (V) Bias_I (nA)
170.0 58.3720
180.0 57.9614
190.0 56.8849
200.0 58.5380

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)