SN 1087 Pre-Encap summary


SN
1087
Status
Pre-Encap
Test Result
Pass
Operator
rlw
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Tall(899)
Start Time
2004/05/05 14:30:29
End Time
2004/05/05 14:49:10
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.7235
4.0 1.1447
6.0 1.6473
8.0 2.2218
10.0 2.6936
15.0 5.1812
20.0 6.7260
Bias_V (V) Bias_I (nA)
30.0 14.9586
40.0 20.1988
50.0 22.2612
60.0 25.1021
70.0 27.7424
80.0 32.0699
90.0 30.4985
Bias_V (V) Bias_I (nA)
100.0 33.6487
110.0 33.7462
120.0 36.2948
130.0 37.0535
140.0 36.5468
150.0 38.7224
160.0 40.0160
Bias_V (V) Bias_I (nA)
170.0 40.7009
180.0 42.5209
190.0 45.9290
200.0 48.1585

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)