SN 1088 Pre-Encap summary


SN
1088
Status
Pre-Encap
Test Result
Pass*
Operator
rlw
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Tall(899)
Start Time
2004/05/04 12:05:57
End Time
2004/05/04 12:23:41
Dead or Hot channels
[(12,33),(12,34)]
Bad Gain or Noise channels
[(12,33),(12,34)]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6437
4.0 1.1272
6.0 1.6702
8.0 2.2897
10.0 2.9364
15.0 6.1755
20.0 8.7210
Bias_V (V) Bias_I (nA)
30.0 22.7563
40.0 30.9079
50.0 38.3116
60.0 42.7549
70.0 48.6358
80.0 49.8341
90.0 55.2522
Bias_V (V) Bias_I (nA)
100.0 57.7730
110.0 57.7803
120.0 59.1383
130.0 61.2886
140.0 61.1776
150.0 62.5760
160.0 63.1091
Bias_V (V) Bias_I (nA)
170.0 63.2524
180.0 61.1624
190.0 62.2366
200.0 62.4385

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)