SN 269 Final summary


SN
269
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/06 07:49:32
End Time
2004/05/06 08:07:11
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 2.3316
4.0 3.3919
6.0 2.3948
8.0 3.0299
10.0 5.1981
15.0 4.7556
20.0 6.6780
Bias_V (V) Bias_I (nA)
30.0 15.7468
40.0 19.2035
50.0 23.3343
60.0 26.2932
70.0 28.1891
80.0 29.2877
90.0 30.5883
Bias_V (V) Bias_I (nA)
100.0 32.8580
110.0 34.9543
120.0 34.1136
130.0 36.5508
140.0 36.0429
150.0 37.7982
160.0 38.1707
Bias_V (V) Bias_I (nA)
170.0 41.0829
180.0 41.2070
190.0 40.7695
200.0 44.1173

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)