SN 309 Pre-Encap summary


SN
309
Status
Pre-Encap
Test Result
Pass
Operator
DPK
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/07 13:12:08
End Time
2004/05/07 13:30:34
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 2.6574
4.0 1.6018
6.0 2.2250
8.0 4.2472
10.0 3.4715
15.0 4.8603
20.0 5.4612
Bias_V (V) Bias_I (nA)
30.0 11.1020
40.0 14.1442
50.0 14.9075
60.0 15.9329
70.0 16.2263
80.0 19.0410
90.0 19.7334
Bias_V (V) Bias_I (nA)
100.0 20.4092
110.0 24.0161
120.0 24.8832
130.0 25.2942
140.0 24.4508
150.0 27.2513
160.0 27.7240
Bias_V (V) Bias_I (nA)
170.0 30.0413
180.0 30.1493
190.0 34.1117
200.0 35.6785

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)