SN 314 Final summary


SN
314
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/30 07:00:36
End Time
2004/04/30 07:18:24
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6293
4.0 1.1387
6.0 1.5837
8.0 2.1719
10.0 2.7368
15.0 5.8056
20.0 8.2767
Bias_V (V) Bias_I (nA)
30.0 23.4794
40.0 31.0117
50.0 36.9245
60.0 43.8093
70.0 48.8795
80.0 51.0828
90.0 54.0741
Bias_V (V) Bias_I (nA)
100.0 54.2126
110.0 56.6618
120.0 57.4931
130.0 57.6932
140.0 55.8755
150.0 57.1421
160.0 57.9554
Bias_V (V) Bias_I (nA)
170.0 56.2854
180.0 57.1559
190.0 56.3693
200.0 54.3650

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)