SN 260 Pre-Encap summary


SN
260
Status
Pre-Encap
Test Result
Pass
Operator
rlw
TE_Config
007
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/19 11:17:44
End Time
2004/04/19 11:36:35
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5344
4.0 0.9612
6.0 1.5089
8.0 2.1237
10.0 2.7731
15.0 6.0702
20.0 8.4887
Bias_V (V) Bias_I (nA)
30.0 22.0098
40.0 28.3240
50.0 36.4667
60.0 42.0518
70.0 48.6344
80.0 52.6559
90.0 53.4497
Bias_V (V) Bias_I (nA)
100.0 55.8071
110.0 58.4466
120.0 59.5865
130.0 58.6124
140.0 59.3825
150.0 60.2835
160.0 61.9985
Bias_V (V) Bias_I (nA)
170.0 59.9005
180.0 58.7445
190.0 59.8456
200.0 58.6568

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)