SN 271 Pre-Encap summary


SN
271
Status
Pre-Encap
Test Result
Pass*
Operator
mutsumi
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/13 15:51:05
End Time
2004/04/13 16:15:23
Dead or Hot channels
[(13,40),(13,41),(13,52),(13,53)]
Bad Gain or Noise channels
[(13,40),(13,41),(13,52),(13,53)]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6638
4.0 1.2426
6.0 1.7904
8.0 2.4041
10.0 3.0582
15.0 6.4299
20.0 8.8606
Bias_V (V) Bias_I (nA)
30.0 23.2359
40.0 32.3220
50.0 37.4287
60.0 44.7628
70.0 48.4727
80.0 52.4852
90.0 53.7083
Bias_V (V) Bias_I (nA)
100.0 56.2349
110.0 58.9098
120.0 61.4961
130.0 61.2722
140.0 61.1179
150.0 61.6911
160.0 61.3172
Bias_V (V) Bias_I (nA)
170.0 62.1519
180.0 60.2503
190.0 61.5778
200.0 61.9168

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)