SN 296 Final summary


SN
296
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
009
Software_V
rel-1-3-4
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/11 09:19:58
End Time
2004/05/11 09:36:58
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.8007
4.0 1.3570
6.0 1.8647
8.0 2.4118
10.0 2.9706
15.0 5.9633
20.0 8.2892
Bias_V (V) Bias_I (nA)
30.0 21.4970
40.0 29.9533
50.0 36.9253
60.0 42.2590
70.0 45.7486
80.0 48.6802
90.0 52.3043
Bias_V (V) Bias_I (nA)
100.0 54.6657
110.0 53.6294
120.0 56.0846
130.0 53.4696
140.0 55.3313
150.0 52.6415
160.0 55.4511
Bias_V (V) Bias_I (nA)
170.0 55.1212
180.0 53.4055
190.0 55.4759
200.0 55.5745

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)