SN 302 Final summary


SN
302
Status
Final
Test Result
Pass
Operator
rlw
TE_Config
009
Software_V
rel-1-3-4
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/13 08:52:24
End Time
2004/05/13 09:09:22
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6637
4.0 1.2331
6.0 1.7978
8.0 2.3110
10.0 2.7336
15.0 5.0204
20.0 6.1870
Bias_V (V) Bias_I (nA)
30.0 15.1193
40.0 15.6668
50.0 20.6923
60.0 23.2830
70.0 24.1430
80.0 27.4662
90.0 29.1093
Bias_V (V) Bias_I (nA)
100.0 28.8528
110.0 31.1305
120.0 32.1281
130.0 32.4715
140.0 32.7525
150.0 34.4251
160.0 35.2253
Bias_V (V) Bias_I (nA)
170.0 36.6879
180.0 36.4467
190.0 40.9559
200.0 44.0852

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)