SN 307 Pre-Encap summary


SN
307
Status
Pre-Encap
Test Result
Pass
Operator
rlw
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/05 13:57:52
End Time
2004/05/05 14:20:10
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6353
4.0 1.0721
6.0 1.5112
8.0 1.9838
10.0 2.4588
15.0 4.8210
20.0 6.2473
Bias_V (V) Bias_I (nA)
30.0 14.0803
40.0 20.4662
50.0 21.4565
60.0 24.2608
70.0 25.9763
80.0 27.7550
90.0 30.0914
Bias_V (V) Bias_I (nA)
100.0 31.8165
110.0 33.2211
120.0 34.9826
130.0 33.6155
140.0 37.2669
150.0 37.4084
160.0 39.4798
Bias_V (V) Bias_I (nA)
170.0 40.7339
180.0 43.2025
190.0 45.3514
200.0 48.7410

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)