SN 309 Final summary


SN
309
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
009
Software_V
rel-1-3-4
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/19 10:38:04
End Time
2004/05/19 10:56:08
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.7206
4.0 1.2756
6.0 1.8205
8.0 2.4530
10.0 2.9322
15.0 6.0526
20.0 8.4119
Bias_V (V) Bias_I (nA)
30.0 22.6585
40.0 27.7139
50.0 35.0220
60.0 42.2327
70.0 46.8316
80.0 49.7575
90.0 51.3639
Bias_V (V) Bias_I (nA)
100.0 51.9613
110.0 52.8278
120.0 52.2571
130.0 51.8822
140.0 52.8072
150.0 53.1403
160.0 52.7246
Bias_V (V) Bias_I (nA)
170.0 52.2084
180.0 53.1120
190.0 51.2415
200.0 53.0058

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)