SN 259 Final summary


SN
259
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/30 07:48:41
End Time
2004/04/30 08:08:24
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.7458
4.0 1.2816
6.0 1.9316
8.0 2.5911
10.0 3.1630
15.0 6.7041
20.0 8.9997
Bias_V (V) Bias_I (nA)
30.0 23.4728
40.0 30.7775
50.0 35.8283
60.0 41.2323
70.0 45.8373
80.0 47.4712
90.0 50.0522
Bias_V (V) Bias_I (nA)
100.0 50.9897
110.0 51.6832
120.0 51.9261
130.0 53.1113
140.0 52.9255
150.0 51.5348
160.0 52.0726
Bias_V (V) Bias_I (nA)
170.0 51.3543
180.0 51.0918
190.0 51.6112
200.0 49.2883

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)