SN 260 Post-BurnIn summary


SN
260
Status
Post-BurnIn
Test Result
Pass
Operator
rlw
TE_Config
002
Software_V
rel-1-3-4
Reference MCM S/N
new_06
Location
SLAC
GTRC version
7
Board type
Short(898)
Start Time
2004/05/23 13:49:46
End Time
2004/05/23 14:06:29
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6642
4.0 1.3086
6.0 1.5661
8.0 1.6279
10.0 2.1127
15.0 4.0172
20.0 5.5950
Bias_V (V) Bias_I (nA)
30.0 13.1750
40.0 16.5089
50.0 19.8090
60.0 22.0181
70.0 24.0700
80.0 25.7425
90.0 27.4445
Bias_V (V) Bias_I (nA)
100.0 28.8765
110.0 29.8993
120.0 31.1641
130.0 32.1134
140.0 33.1738
150.0 34.1590
160.0 34.9628
Bias_V (V) Bias_I (nA)
170.0 35.8051
180.0 36.0798
190.0 36.9061
200.0 37.6460

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)