SN 269 Pre-Encap summary


SN
269
Status
Pre-Encap
Test Result
Pass
Operator
Mutsumi
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/29 14:24:59
End Time
2004/04/29 14:42:31
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6712
4.0 1.2127
6.0 1.7868
8.0 2.5198
10.0 3.2764
15.0 6.7666
20.0 9.2163
Bias_V (V) Bias_I (nA)
30.0 23.5541
40.0 31.0747
50.0 34.4511
60.0 38.8828
70.0 41.7860
80.0 43.4680
90.0 46.6108
Bias_V (V) Bias_I (nA)
100.0 47.6196
110.0 46.7357
120.0 47.2735
130.0 48.6761
140.0 49.3272
150.0 51.2850
160.0 50.9749
Bias_V (V) Bias_I (nA)
170.0 49.4240
180.0 53.2195
190.0 52.8908
200.0 53.8703

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)