SN 271 Final summary


SN
271
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/19 08:37:02
End Time
2004/04/19 08:54:18
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.7510
4.0 1.2671
6.0 1.9020
8.0 2.4869
10.0 3.1580
15.0 6.6154
20.0 8.9203
Bias_V (V) Bias_I (nA)
30.0 21.7230
40.0 31.4652
50.0 38.4512
60.0 42.8862
70.0 46.6399
80.0 49.8465
90.0 52.4149
Bias_V (V) Bias_I (nA)
100.0 53.6229
110.0 53.6996
120.0 54.7301
130.0 55.4532
140.0 54.9839
150.0 55.8242
160.0 55.9477
Bias_V (V) Bias_I (nA)
170.0 56.2103
180.0 53.6353
190.0 55.9252
200.0 55.5187

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)