SN 307 Final summary


SN
307
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
009
Software_V
rel-1-3-4
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/20 08:39:11
End Time
2004/05/20 08:56:57
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5436
4.0 0.9329
6.0 1.4081
8.0 1.9704
10.0 2.5979
15.0 5.7483
20.0 8.0335
Bias_V (V) Bias_I (nA)
30.0 21.6810
40.0 30.8109
50.0 36.2924
60.0 41.5157
70.0 45.4993
80.0 49.1376
90.0 51.5771
Bias_V (V) Bias_I (nA)
100.0 50.9823
110.0 52.5867
120.0 53.6988
130.0 53.0723
140.0 53.9086
150.0 52.2222
160.0 55.0667
Bias_V (V) Bias_I (nA)
170.0 53.3515
180.0 53.6150
190.0 53.6247
200.0 53.7133

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)