SN 308 Pre-Encap summary


SN
308
Status
Pre-Encap
Test Result
Pass
Operator
mutsumi
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/13 14:05:44
End Time
2004/04/13 14:23:13
Dead or Hot channels
[]
Bad Gain or Noise channels
[]

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6798
4.0 1.2632
6.0 1.7454
8.0 2.3741
10.0 3.0556
15.0 6.3447
20.0 9.1120
Bias_V (V) Bias_I (nA)
30.0 22.6616
40.0 30.1075
50.0 37.5366
60.0 42.0802
70.0 49.3617
80.0 52.4718
90.0 54.3994
Bias_V (V) Bias_I (nA)
100.0 56.5838
110.0 59.8495
120.0 61.6129
130.0 61.1043
140.0 62.0308
150.0 62.3069
160.0 62.0989
Bias_V (V) Bias_I (nA)
170.0 63.4447
180.0 64.0303
190.0 62.4740
200.0 61.9295

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)