SN 237 Final summary


SN
237
Status
Final
Test Result
Pass
Operator
DPK
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Tall(899)
Start Time
2004/05/07 07:14:47
End Time
2004/05/07 07:33:29
Dead or Hot channels
[]
Bad Gain or Noise channels
[]
Bad trigger channels
No Data
Number of bad response channels
0
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data
Number of bad channels in total
0

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 -1.1408
4.0 3.9516
6.0 2.8858
8.0 3.0231
10.0 4.4192
15.0 4.7405
20.0 6.3526
Bias_V (V) Bias_I (nA)
30.0 9.7064
40.0 10.1260
50.0 14.4993
60.0 16.0177
70.0 17.9135
80.0 19.8002
90.0 22.0292
Bias_V (V) Bias_I (nA)
100.0 20.8605
110.0 22.6369
120.0 22.5426
130.0 24.8394
140.0 26.0804
150.0 24.1736
160.0 25.8703
Bias_V (V) Bias_I (nA)
170.0 27.5488
180.0 27.8747
190.0 30.3883
200.0 34.9501

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection

Pitch adapter bias connection