SN 237 Pre-Encap summary


SN
237
Status
Pre-Encap
Test Result
Pass
Operator
rlw
TE_Config
009
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/04 10:52:11
End Time
2004/05/04 11:09:52
Dead or Hot channels
[]
Bad Gain or Noise channels
[]
Bad trigger channels
No Data
Number of bad response channels
0
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data
Number of bad channels in total
0

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6145
4.0 1.1290
6.0 1.4219
8.0 2.3841
10.0 3.1058
15.0 6.9051
20.0 9.4702
Bias_V (V) Bias_I (nA)
30.0 23.1317
40.0 33.3113
50.0 39.7271
60.0 45.0800
70.0 49.1260
80.0 51.2920
90.0 54.4085
Bias_V (V) Bias_I (nA)
100.0 55.3837
110.0 56.7080
120.0 58.6071
130.0 84.9650
140.0 58.5748
150.0 57.1458
160.0 58.5999
Bias_V (V) Bias_I (nA)
170.0 59.1108
180.0 57.7175
190.0 55.2380
200.0 56.6701

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection

Pitch adapter bias connection