SN 260 Pre-Encap summary


SN
260
Status
Pre-Encap
Test Result
Pass
Operator
rlw
TE_Config
007
Software_V
rel-1-3-3
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/19 11:17:44
End Time
2004/04/19 11:36:35
Dead or Hot channels
[]
Bad Gain or Noise channels
[]
Bad trigger channels
No Data
Number of bad response channels
0
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data
Number of bad channels in total
0

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5344
4.0 0.9612
6.0 1.5089
8.0 2.1237
10.0 2.7731
15.0 6.0702
20.0 8.4887
Bias_V (V) Bias_I (nA)
30.0 22.0098
40.0 28.3240
50.0 36.4667
60.0 42.0518
70.0 48.6344
80.0 52.6559
90.0 53.4497
Bias_V (V) Bias_I (nA)
100.0 55.8071
110.0 58.4466
120.0 59.5865
130.0 58.6124
140.0 59.3825
150.0 60.2835
160.0 61.9985
Bias_V (V) Bias_I (nA)
170.0 59.9005
180.0 58.7445
190.0 59.8456
200.0 58.6568

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection