SN 262 Pre-Encap summary


SN
262
Status
Pre-Encap
Test Result
Pass
Operator
mutsumi
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/13 11:08:32
End Time
2004/04/13 11:26:50
Dead or Hot channels
[]
Bad Gain or Noise channels
[]
Bad trigger channels
No Data
Number of bad response channels
0
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data
Number of bad channels in total
0

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.5385
4.0 0.9948
6.0 1.5722
8.0 2.2661
10.0 2.8851
15.0 6.2870
20.0 8.7108
Bias_V (V) Bias_I (nA)
30.0 22.6182
40.0 30.2268
50.0 36.9659
60.0 40.7791
70.0 46.9941
80.0 51.2687
90.0 53.2810
Bias_V (V) Bias_I (nA)
100.0 54.6774
110.0 56.5778
120.0 58.2665
130.0 57.7464
140.0 56.9688
150.0 58.7928
160.0 57.3121
Bias_V (V) Bias_I (nA)
170.0 55.8169
180.0 57.2426
190.0 55.8692
200.0 57.3944

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection

Pitch adapter bias connection