SN 271 Pre-Encap summary


SN
271
Status
Pre-Encap
Test Result
Pass*
Operator
mutsumi
TE_Config
007
Software_V
rel-1-3-2
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/04/13 15:51:05
End Time
2004/04/13 16:15:23
Dead or Hot channels
[(13,40),(13,41),(13,52),(13,53)]
Bad Gain or Noise channels
[(13,40),(13,41),(13,52),(13,53)]
Bad trigger channels
No Data
Number of bad response channels
4
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data
Number of bad channels in total
4

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6638
4.0 1.2426
6.0 1.7904
8.0 2.4041
10.0 3.0582
15.0 6.4299
20.0 8.8606
Bias_V (V) Bias_I (nA)
30.0 23.2359
40.0 32.3220
50.0 37.4287
60.0 44.7628
70.0 48.4727
80.0 52.4852
90.0 53.7083
Bias_V (V) Bias_I (nA)
100.0 56.2349
110.0 58.9098
120.0 61.4961
130.0 61.2722
140.0 61.1179
150.0 61.6911
160.0 61.3172
Bias_V (V) Bias_I (nA)
170.0 62.1519
180.0 60.2503
190.0 61.5778
200.0 61.9168

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection

Pitch adapter bias connection