SN 302 Final summary


SN
302
Status
Final
Test Result
Pass
Operator
rlw
TE_Config
009
Software_V
rel-1-3-4
Reference MCM S/N
1077
Location
Teledyne
GTRC version
7
Board type
Short(898)
Start Time
2004/05/13 08:52:24
End Time
2004/05/13 09:09:22
Dead or Hot channels
[]
Bad Gain or Noise channels
[]
Bad trigger channels
No Data
Number of bad response channels
0
Disconnected pitch-adapter channels
No Data
Number of disconnected pitch-adapter channels
No Data
Number of bad channels in total
0

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.6637
4.0 1.2331
6.0 1.7978
8.0 2.3110
10.0 2.7336
15.0 5.0204
20.0 6.1870
Bias_V (V) Bias_I (nA)
30.0 15.1193
40.0 15.6668
50.0 20.6923
60.0 23.2830
70.0 24.1430
80.0 27.4662
90.0 29.1093
Bias_V (V) Bias_I (nA)
100.0 28.8528
110.0 31.1305
120.0 32.1281
130.0 32.4715
140.0 32.7525
150.0 34.4251
160.0 35.2253
Bias_V (V) Bias_I (nA)
170.0 36.6879
180.0 36.4467
190.0 40.9559
200.0 44.0852

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)

TREQ response (TM713)

Pitch adapter signal channel connection

Pitch adapter bias connection