SN 359 Final summary


SN
359
Status
Final
Operator
Mutsumi
TE_Config
001
Software_V
No Data
Reference MCM S/N
No Data
Location
Teledyne
GTRC version
6
Board type
Short
Start Time
2004/02/26 11:38:24
End Time
2004/02/26 12:02:16
Dead or Hot channels
No Data
Bad Gain or Noise channels
No Data

Power Consumption and LVDS levels

Functionality

Bias leakage current (TM703)

Bias_V (V) Bias_I (nA)
2.0 0.7071
4.0 1.4195
6.0 2.0657
8.0 2.8080
10.0 3.5625
15.0 7.1365
20.0 9.8139
Bias_V (V) Bias_I (nA)
30.0 24.5056
40.0 33.3604
50.0 38.9160
60.0 45.9062
70.0 49.7994
80.0 53.0711
90.0 55.1580
Bias_V (V) Bias_I (nA)
100.0 56.8584
110.0 59.8537
120.0 59.9300
130.0 59.4598
140.0 60.1722
150.0 59.5521
160.0 61.2263
Bias_V (V) Bias_I (nA)
170.0 62.6274
180.0 62.8562
190.0 63.2989
200.0 62.5985

Threshold scan without charge injection (TM710)

Gain and Noise (TM714)

Noise trigger rate threshold scan (TM715)